ABB component drives
ACS150, 0.37 to 4 kW / 0.5 to 5 hp
Catalog
ABB component drives
ABB component drives
ABB component drives are designed for machine
building. These drives are components that are bought
together with other components from a logistical
distributor. The drives are stocked, and the number
of options and variants is optimized for logistical
distribution.
Applications
■ Fans
■ Pumps
■ Gate control
■ Material handling
■ Conveyors
Highlights
■ User-friendly LCD control panel and integrated
potentiometer
■ Flexible mounting alternatives
■ Integrated EMC fi lter
■ Inbuilt brake chopper as standard
■ FlashDrop tool
Feature Advantage Benefi t
User-friendly LCD control panel and
integrated potentiometer
Clear alphanumeric display. Easy set-up and
use.
Time savings
Flexible mounting alternatives Screw or DIN rail mounting, sideways or sideby-
side
One drive type can be used in various designs,
saving installation costs and time
Integrated EMC filter High electromagnetic compatibility Low EMC emissions in selected environments
Inbuilt brake chopper as standard No need for an external brake chopper Space savings, reduced installation cost
FlashDrop tool Faster and easier drive set up and
commissioning for volume manufacturing and
maintenance. The FlashDrop tool enables both
downloading and uploading drive parameters.
Fast, safe and trouble-free parameter setting
without the need to power-up the drive.
Patented.
ABB 3AFE68596114 REV D EN 8.4.2009 3
standard
EN 61800-3 (2004),
product standard
EN 55011, product
Technical specifi cation
EMC standards in general
EN 61800-3/A11
(2000), product
family standard for
industrial, scientifi c
and medical (ISM)
equipment
1st environment,
unrestricted
distribution
Category C1 Group 1
Class B
1st environment,
restricted distribution
Category C2 Group 1
Class A
2nd environment,
unrestricted
distribution
Category C3 Group 2
Class A
2nd environment,
restricted distribution
Category C4 Not applicable
Mains connection
Voltage and power range 1-phase, 200 to 240 V ± 10%
0.37 to 2.2 kW (0.5 to 3 hp)
3-phase, 200 to 240 V ± 10%
0.37 to 2.2 kW (0.5 to 3 hp)
3-phase, 380 to 480 V ± 10%
0.37 to 4 kW (0.5 to 5 hp)
Frequency 48 to 63 Hz
Power factor 0.98
Motor connection
Voltage 3-phase, from 0 to Usupply
Frequency 0 to 500 Hz
Continuous loading
capability
(constant torque at a max. ambient
temperature 40ºC)
Rated output current I2N
Overload capability
(at a max. ambient temperature of 40ºC)
At heavy duty use 1.5 x I2N for 1 minute
every 10 minutes
At start 1.8 x I2N for 2 s
Switching frequency
Default
Selectable
4 kHz
4 to 16 kHz with 4 kHz steps
Acceleration time 0.1 to 1800 s
Deceleration time 0.1 to 1800 s
Braking Inbuilt brake chopper as standard
Environmental limits
Ambient temperature -10 to 40 ºC (14 to 104 ºF), no frost
allowed, 50 ºC (122 ºF) with 10%
derating
Altitude
Output current Rated current available at 0 to 1000 m
(0 to 3281 ft) reduced by 1% per 100 m
(328 ft) over 1000 to 2000 m (3281 to
6562 ft)
Relative humidity Lower than 95% (without
condensation)
Degree of protection IP20 / Optional NEMA 1 enclosure
Enclosure colour NCS 1502-Y, RAL 9002, PMS 420 C
Contamination levels
Transportation
Storage
Operation
IEC 721-3-3
No conductive dust allowed
Class 1C2 (chemical gases)
Class 1S2 (solid particles)
Class 2C2 (chemical gases)
Class 2S2 (solid particles)
Class 3C2 (chemical gases)
Class 3S2 (solid particles)
Chokes
AC input chokes External option.
For re duc ing THD in partial loads and
to comply with EN 61000-3-2.
AC output chokes External option.
To achieve longer motor cables.
Programmable control connections
One analog input
Voltage signal
Current signal
Potentiometer reference value
Resolution
Accuracy
0 (2) to 10 V, Rin > 312 k
0 (4) to 20 mA, Rin = 100
10 V ± 1% max. 10 mA, R < 10 k
0.1 %
± 2%
Auxiliary voltage 24 V DC ± 10%, max. 200 mA
Five digital inputs 12 to 24 V DC with internal or external
supply, PNP and NPN, pulse train
0 to 10 kHz.
Input impedance 2.4 k
One relay output
Type
Maximum switching voltage
Maximum switching current
Maximum continuous current
NO + NC
250 V AC/30 V DC
0.5 A/30 V DC; 5 A/230 V AC
2 A rms
Product compliance
Low voltage Directive 73/23/EEC with supplements
Machinery Directive 98/37/EC
EMC Directive 89/336/EEC with supplements
Quality assurance system ISO 9001
Environmental system ISO 14001
UL, cUL, CE, C-Tick and GOST R approvals
EMC according to EN61800-3
2nd environment fi lter, unrestricted distribution, C3 with 30 m (98 ft)
cable, inbuilt as standard.
4 3AFE68596114 REV D EN 8.4.2009 ABB
Ratings, types, voltages and construction
Type code
In column 4 on the right is the unique reference
number that clearly indentifi es your drive by power
rating and frame size. Once you have selected the
type code, the frame size (column 5) can be used to
determine the drives dimensions, shown below.
Voltages
ACS150 is available in two voltage ranges:
2 = 200 - 240 V
4 = 380 - 480 V
Insert either "2" or “4”, depending on your chosen
voltage, into the type code shown on the right.
Construction
"01X" and "03X" within the type code varies depending
on the drive phase and EMC fi ltering. Choose below
the one you need.
01 = 1-phase
03 = 3-phase
E = EMC fi lter connected, 50 Hz frequency
U = EMC fi lter disconnected, 60 Hz frequency
(In case the fi lter is required it can easily
be connected.)
X within the type code stands for E or U.
Dimensions
H1 = Height without fastenings and clamping plate.
H2 = Height with fastenings but without clamping plate.
H3 = Height with fastenings and clamping plate.
H4 = Height with fastenings and NEMA 1 connection box.
H5 = Height with fastenings, NEMA 1 connection box and hood.
|